Current Feature Projects | |
---|---|
Airtrunk Melbourne Data Centre Stage 1 (ATMELS1) | |
Project Value - Undisclosed Builder - FDC Construction & Fitout (VIC) Pty. Ltd. Architect - DEM (Aust) Pty. Ltd. ecoMECH - Construction Mechanical Design Documentation, Mechanical Building Information Modelling (BIM) Design and Coordination. Project Description
Key Features
| |
Victorian New Schools PPP Project | |
Project Value - $291m Builder - Watpac Construction (Vic) Pty. Ltd. Architect - ClarkeHopkinsClarke ecoMECH - Detailed Mechanical Design Documentation As part of the Learning Communities Victoria (LCV) consortium, the successful tenderer for Victoria's current New Schools Public Private Partnership Project (PPP), ecoMECH provided mechanical advice and documentation to 8 of the 15 high priority new government schools.
The project features a range of school types tailored to the needs of the community, including primary schools, prep to year 9 schools, prep to year 12 schools, a special school integrated primary, and a special development school for children with a high level of intellectual disability. Early learning facilities are also being integrated into the campus at six of the schools involved in the PPP program.
The schools are located across a number of Victoria's fastest growing metropolitan and regional communities including Bannockburn, Epping North, Point Cook South, North Geelong, Armstrong Creek, Torquay North, Mernda South, Casey Central East, Pakenham South West, Heather Grove and Cranbourne South West. www.dtf.vic.gov.au/partnerships-victoria-ppp-projects/new-schools-ppp | |
Completed Feature Projects | |
Chadstone Corporate Office Tower, Bus Interchange and Myer Carpark upgrade | |
Approximate Project Value - Part of major upgrade works totalling $580m Builder - Probuild Construction (Vic) Pty Ltd. Architect - Bates Smart Pty Ltd. ecoMECH - Construction Mechanical Design Documentation, ESD advise and Energy Modelling for Green Star As-Built & NABERS predictions and assessments. The project involves the construction of a 10 level 17,000sqm PCA Grade-A Commercial Office Tower above 25,000sqm over 4 levels of basement car park. In addition to a new 14 bay Bus Interchange Facility and an additional 8,000sqm above ground deck to the existing Myer Carpark. The Commercial Tower is designed to achieve a 5 Star Green Star Design & As-built Rating, and 4.5 Star NABERS Energy rating. ecoMECH have taken a lead role in the predictive energy modelling for the As-Built Green Star and NABERS assessments to ensure that the completed building complies with the these project requirements. ecoMECH have worked hand in hand with services consultant Norman Disney and Young who provided the original mechanical, original energy modelling, fire, hydraulic, electrical, communication and security designs for the project. Key Features
| |